ARIFUHangzhou Airifu Environmental Technology
SiC ceramic membranes

Silicon carbide: the membrane you can clean with anything

The material survives pH 1 to 14, which means strong acid and caustic cleaning stay on the table when flux drops. That single property is why SiC holds its place in mining water, oily water and seawater pre-treatment.

20 nm and 50 nm · ≥2000 LMH/bar pure-water flux · 20-year quoted material life

Property by property

PropertySiCAluminaPolymeric (PVDF/PES)
Pure-water flux≥2000 LMH/bar≈1/3 of SiC≈1/20 of SiC
pH range1–142–122–11, narrow with cleaning
Hardness9.2 Mohs9 Mohs—
Contact angle0.3° (super-hydrophilic)10–40°40–80°
Cleaning regimeStrong acid and caustic, high temperatureMild acid/causticLimited; oxidants degrade the polymer
Quoted life20 years (material)5–10 years2–5 years
Weak pointUnit cost, brittleness, needs proper pre-treatmentLower flux, narrower pHCannot be chemically restored

Elements we make

Tubular for high-solids and high-viscosity duty, flat sheet for seawater pre-treatment at large flow, multi-channel for a high area-to-volume ratio.

ModelElementPore sizeFlux (LMH)LengthHousing
SiC-T-1200Tubular 1200 × 4020 nm300–4001200 mmSUS316L
SiC-T-1000Tubular 1000 × 4020 nm300–4001000 mmSUS316L
SiC-P-250Flat sheet 250 × 25050 nm200–300250 mmSUS316L
SiC-M-19Multi-channel 19 channels20 nm300–5001000 mmSUS316L
SiC-M-37Multi-channel 37 channels20 nm400–6001000 mmSUS316L

Where SiC changes the outcome

Mine water

Cui Jiagou, 2×75 m³/h: flotation ahead of 20 nm SiC, effluent 0.18 NTU, TSS removal 94%. The flotation does the coarse work so the membrane is not asked to store coal fines.

Seawater RO pre-treatment

Ningbo, 1160 m³/h flat-sheet SiC: cleaning cycle held at 20–25 days with effluent at 0.2 NTU, on a site where the polymeric train had been cleaned weekly.

Oily water

Produced water after hypergravity separation, to reach <10 mg/L oil for reinjection. The membrane is the last cut, not the first.

Inside the generator

The same 20 nm membrane is the gas-dispersion medium in ARFU flotation and NEO ozone units — a uniform pore gives a narrow bubble distribution.

Two things buyers get wrong

  • Designing at catalogue flux. Use a fraction of the clean-water figure and let the fouling allowance be real. A membrane system sized at 600 LMH will be cleaned constantly; the same system designed at 200 LMH will not.
  • Treating "20-year life" as maintenance-free. It describes the chemical stability of the material under specified pre-treatment and correct cleaning. Replacement intervals depend on feed quality and on whether the cleaning is actually done.

Membrane selection starts with the cleaning regime

Tell us what you need to clean off, and how often you can afford to stop. That decides the pore size, the element type and the pre-treatment — in that order.

Discuss a membrane duty → Fouling control